2 General Information about Integrated Safety Systems
2.10 Customer Support
Offer
SPL configuration
Commissioning
Acceptance report
Approval procedure
Workshop
Hotline
On-site service
2-44
SINUMERIK 840D/SIMODRIVE 611 digital SINUMERIK Safety Integrated (FBSI) - Edition 11.03
Description of services
•
Safely-reduced speed (SG)
•
Safe software limit switch (SE), safe software cam (SN)
are integrated into the circuit diagram of the machine. External safety
elements (e.g. door locking, EMERGENCY STOP button, ...) are either
configured conventionally or logically combined via the "safe
programmable logic" (SPL) function.
Based on the standard configuration the following objects are created for
SPL:
•
Function diagram
•
Logic program for the PLC area
•
Logic program for the NC area
•
Required data modules (e.g. DB18)
Linking these objects into the overall system
On the basis of the configuration that has been created, the safety
functions are commissioned. The customer provides the machine so that
the drives can be traversed and the control cabinet is wired according to
the configuration.
On the basis of the submitted configuration documentation and
commissioning, an acceptance report for the safety functions is drawn-
up. These include:
•
Description of the machine (name, type, ...)
•
Description of the safety and operating concepts
•
Description of the axis-specific safety functions
•
Testing of all safety functions including the SPL logic
•
Records of the test results
The customer will receive the acceptance report as hardcopy and on an
electronic data medium.
Support with processing and line of argument for the approval procedure
by certified bodies (e.g. regulatory bodies) or large end customers.
Workshops on the subject of machine safety are adapted to customer's
specific requirements and can take place on the customer's premises, if
necessary. Possible contents:
•
Machinery Directive, Standards in general
•
C standards (machine-specific)
•
Hazard analysis, risk analysis
•
Control categories (to EN 954-1)
•
SINUMERIK Safety Integrated
•
Configuration, machine data
•
Start-up
•
Acceptance report
An expert for 'SINUMERIK Safety Integrated
hotline number should serious errors or problems occur during installation
and commissioning.
Experts analyze problems encountered on-site. The causes are
eliminated or a remedy is drawn-up and implemented where necessary.
- function and system description
' can be reached at the
© Siemens AG 2003 All Rights Reserved
11.03