Huawei E9000 Troubleshooting Manual page 96

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
Fault
Symptom
A server
in standby
mode
cannot
power on.
(The
power
indicator
is steady
yellow.)
Issue 20 (2020-09-25)
Handling Procedure
2. Contact Huawei technical
support.
1. Collect iMana 200 or iBMC
logs, and query the complex
programmable logical device
(CPLD) register to determine
whether the power supply link
to the mainboard has failed.
2. If the server cannot be
powered on by pressing the
power button, check whether
the hardware of the
component where the power
button is located is faulty.
3. Check whether the mainboard
and DIMMs are installed
properly.
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Quick Recovery Method
2. Keep the compute node
removed and add a jumper
cap to the Clear_BMC_PW
pin on the mainboard to
attempt to restore the
default settings of iMana
200 or iBMC. Then reinstall
the compute node.
3. Replace the mainboard or
BMC board.
1. Remove the external PCIe
devices such as NICs and FC
HBAs. Then check whether
the fault is rectified.
● If yes, no further action is
required.
● If no, go to 2.
2. Retain only the minimum
server configuration (a
single CPU, a single
mainboard, and a single
DIMM). Then check whether
the fault is rectified.
● If yes, no further action is
required.
● If no, go to 3.
3. Check whether the CPUs,
mainboard, and memory
modules are faulty, and
replace the faulty
components.
87

Hide quick links:

Advertisement

Table of Contents
loading