Huawei E9000 Troubleshooting Manual page 72

Hide thumbs Also See for E9000:
Table of Contents

Advertisement

Huawei Servers
Troubleshooting
Indicator
Fan module
operating status
indicator on the
X6800
Issue 20 (2020-09-25)
Status
Blinking green
(four times every
second)
Steady red
Blinking red
Off
Steady green
Steady red
Copyright © Huawei Technologies Co., Ltd.
5 Diagnosing and Rectifying Faults
Meaning
The
communication
between the fan
module and the
iBMC is abnormal.
The fan module
hardware or
backplane is
faulty.
The fan module
has an alarm, or
the fan module
hardware or
backplane is
damaged.
The fan module is
not powered on.
The fan module is
operating
properly.
The fan module is
faulty.
Diagnosis
Log in to the
iBMC WebUI and
check whether the
iBMC is running
properly.
● If the iBMC
software is
abnormal,
upgrade the
iBMC software
or replace the
high-
performance
fusion console
(HFC). For
details, see
6
Software and
Firmware
Upgrade.
● If the iBMC is
normal, reseat
the fan
module. If the
alarm persists,
replace the fan
module.
Reseat the fan
module. If the
alarm persists,
replace the fan
module.
Reseat the fan
module. If the
alarm persists,
replace the fan
module.
N/A
N/A
Replace the faulty
fan module.