Load Analyzer; Temperature 2 Fault Limit; Motor Load Curve; Zero Speed Load - ABB ACS560 Quick Installation And Start-Up Manual

General purpose drives standard control program
Hide thumbs Also See for ACS560:
Table of Contents

Advertisement

Index
Name
Disabled[0]
Estimated temperature[1]
KTY84 analog I/O
1 × Pt100 analog I/O[5]
2 × Pt100 analog I/O[6]
35.12
Temperature 1 fault limit
35.13
Temperature 1 warning limit
35.14
Temperature 1 AI source
Not selected[0]
35.21
Temperature 2 source
35.22

Temperature 2 fault limit

35.23
Temperature 2 warning limit
35.24
Temperature 2 AI source
35.50
Motor ambient temperature
35.51

Motor load curve

35.52

Zero speed load

35.53
Break point
35.54
Motor nominal temperature
rise
35.55
Motor thermal time constant
35.56
Motor overload action
35.57
Motor overload class

36 Load analyzer

36.01
PVL signal source
Range/List
3 × Pt100 analog I/O[7]
Direct temperature[11]
KTY83 analog I/O[12]
1 × Pt1000 analog I/O[13]
2 × Pt1000 analog I/O[14]
-60...5000 °C
-60...5000 °C
0...2
AI1 actual value[1]
AI2 actual value[2]
See parameter 35.11
Temperature 1 source
-60...5000 °C
-60...5000 °C
See parameter 35.14
Temperature 1 AI source
-60...100 °C
50...150
25...150
1.00 ... 500.00
0...300 °C
100...10000
No action[0], Warning
only[1], and Warning and
fault[2]
Class 5[0], Class 10[1],
Class 20[2], Class 30,[3]
Class 40[4]
-
Parameter listing 85
Unit
Default
3 × Pt1000 analog I/O[15]
NI 1000[16]
PTC analog I/O [20]
PTC AI/DI Voltage Divider
tree[23]
°C
130 °C
°C
110 °C
-
Not selected[0]
Other...
-
Estimated temper-
ature[1]
°C
130 °C
°C
110 °C
-
Not selected[0]
°C
20
%
100
%
70
Hz
45.00
°C
80
s
256
-
Warning and
fault[2]
-
Class 20[2]
-
Motor current[4]
EN
HI

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents