2.3.1 Mounting a Device to a Specified Location

The USG6330/6350/6360/6370/6380/6390/6530/6550/6570/6620/6630 can be mounted in a
19-inch standard cabinet. When no cabinet is available, you can mount the
USG6330/6350/6360/6370/6380/6390/6530/6550/6570/6620/6630 on a workbench.

2.3.1.1 Mounting a Device in a Cabinet

The USG6330/6350/6360/6370/6380/6390/6530/6550/6570/6620/6630 can be mounted in a
19-inch standard cabinet through L-shape guide rails or adjustable guide rails.
Context
The L-shape guide rails and adjustable guide rails are optional and will not be delivered with
the USG. You can purchase them from EdgeWave if required.
Required instruments:
Before installing the USG, check the following items:
You can place either end of the USG chassis towards the cabinet door. In this manual, the
front panel of the USG is towards the cabinet door.
Procedure
Step 1 Install mounting ears on the chassis.
Use a Phillips screwdriver to fix the mounting ears to both sides of the chassis with M4
screws, as shown in
Issue 03 (2015-01-26)
Phillips screwdriver
Floating mounting bar
The cabinet is stable.
The adjustable length of an adjustable guide rail is from 400 mm to 600 mm. You can
install it to a 600 mm to 800 mm (depth) cabinet. Before you use an adjustable guide rail,
adjust the distance between the front and rear installation angle gauges (mounting
bars/side posts) until meeting the requirements for installing the rail.
The position for the USG in the cabinet is well arranged.
Ensure that the USG is 1 U of clearance from any devices above and below and 150 mm
of clearance from any devices on the right or left.
The device to be installed is staged near the cabinet for convenience.
From the rear perspective of the chassis, the cooling wind of the USG flows in on the left
and front, and is exhausted on the right. When a USG and a device whose cooling wind
flows in on the right and is exhausted on the left are installed in the same cabinet,
adequate space must be reserved between them to avoid thermal cycles.