Overview of Alarms
NCK alarms
7202
Missing option bit for %1: %2 <hex>
Parameters:
%1 = (string) name of the specific .elf file
%2 = (int) required option bit (hex)
Definitions:
Alarm for SIEMENS compile cycles. This alarm appears when the option bit required for a SIEMENS
compile cycle is not set.
Reaction:
NC not ready.
Channel not ready.
Interface signals are set.
Alarm display.
Alarm reaction delay is canceled.
Remedy:
Set the required option bit or delete the .elf file from the Flash File System.
Program
Clear alarm with the RESET key in all channels. Restart part program.
Continuation:
7205
Incompatible OEM transformation channel %1 version NCK %2 CC %3
Parameters:
%1 = (int) channel number
%2 = Transformer interface version NCK
%3 = Transformer interface version OEM
Definitions:
The interface for OEM transformations has changed incompatibly in the system.
Reaction:
NC not ready.
Channel not ready.
Interface signals are set.
Alarm display.
Alarm reaction delay is canceled.
Remedy:
Load the new compile cycle version
Program
Clear alarm with the RESET key in all channels. Restart part program.
Continuation:
7500
Block %1 invalid protection level for command %2 (protection level act.:
%3 prog.: %4)
Parameters:
%1 = Block number
%2 = Programmed command
%3 = Current protection level of the command
%4 = Programmed protection level of the command
Definitions:
On assigning a protection level for a parts program command via REDEF command
- an impermissible parts program command has been programmed
- a protection level has been programmed that is logically smaller (larger in value) than the protection
level currently applicable for this command.
- the relevant definition file has not been protected sufficently against write access. The write
protection of the file must be at least as high as the highest protection level that has been assigned to
a parts program command in this definition file.
Reaction:
Alarm display.
Remedy:
Modify definition files /_N_DEF_DIR/_N_MACCESS_DEF or /_N_DEF_DIR/_N_UAC-CESS_ DEF.
Please see the Siemens Programming Guide or the OEM documentation for the language commands
permissible for the relevant system configurations.
Program
Clear alarm with the RESET key. Restart part program