Siemens SINUMERIK 840Di Diagnostic Manual page 867

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
Extension 2
-
Explanation
Performance 1 and standard cannot run two axes with HSA.
Remedy
Only one HSA axis may be active.
Error code
0048H
Error text
Unexpected measurement system configuration
Extension 1
-
Extension 2
-
Explanation
The PCU extension for direct or indirect measurement systems is incomplete.
Remedy
Check module.
Error code
0049H
Error text
A CCU3 axis was defined as a single-axis model.
Extension 1
-
Extension 2
-
Explanation
-
Remedy
-
Error code
0050H
Error text
Module not supported by drive software.
Extension 1
-
Extension 2
-
Explanation
The drive software cannot be run on this module.
Remedy
Load the drive software for the module or plug in the correct module for the drive soft-
ware.
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Error Codes of Alarm 300500
4-867

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents