Overview of Alarms
NCK alarms
10702
Channel %1 NCK protection zone %2 violated during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
Definitions:
The workpiece-related NCK protection zone has been violated. Note that another tool-related
protection zone is still active. The workpiece-related protected area can be traversed after a new NC
Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Protection zone can be traversed after a new NC Start.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
10703
Channel %1 channel-specific protection zone %2 violated during manual
mode
Parameters:
%1 = Channel number
%2 = Protection zone number
Definitions:
The workpiece-related channel-specific protection zone has been violated. Note that another tool-
related protection zone is still active. The workpiece-related protected area can be traversed after a
new NC Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Protection zone can be traversed after a new NC Start.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
10704
Channel %1 block %2 protection zone monitoring is not guaranteed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
New movements of a geometry axis which have been added could not be allowed for at the time of
block preparation. It is therefore not certain that the protection zones will not be violated. This is just
a warning message without further reactions.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Take other measures to ensure that the geomotry axes motion, including the additional motion, does
not violate the protection zones. (The warning comes nevertheless) or exclude additional motions.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
10706
Channel %1 NCK protection zone %2 reached with axis %3 during
manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
%3 = Axis name
Definitions:
The workpiece-related NCK protection zone has been reached with the specified axis. Note that
another tool-related protection zone is still active. The workpiece-related protection zone can be
traversed when the PLC has issued an enable signal.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Protection zone can be traversed after
enable signal from PLC.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
2-114