Siemens SINUMERIK 840Di Diagnostic Manual page 613

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
100203
Channel switchover key not effective
Definitions:
--
Remedy:
--
100204
Channel on NCU does not exist or is not active
Definitions:
--
Remedy:
--
100300
'%1' not found, continue search without filter!
Parameters:
%1 = --
Definitions:
The search term entered in a list image (e.g. general machine data) was not found.
Remedy:
--
100301
Table cannot be fully generated!
Definitions:
The list image could not be generated due to insufficient memory.
Remedy:
System error, a rebooting may be necessary.
100302
No data available - or no access authorization!
Definitions:
The list image can not be generated, as this data is currently not available.
Example: Local user data is not defined.
Remedy:
--
100303
Paging not possible
Definitions:
You cannot page over, for example, axes, drives or channels, as more axes, drives or channels are
not configured.
Remedy:
--
100304
'%1' not found.
Parameters:
%1 = --
Definitions:
--
Remedy:
--
100350
Display MD saved
Definitions:
- The display machine data is saved via the softkey "Save" in the operating
area start-up, image machine data - display
machine data.
- The display machine data is saved in the start-up basic display after
pressing the softkey "LCD brighter" or "LCD darker" (this setting will remain at the next start-up).
- As of SW 4.1: If the display options are changed in the machine data images,
the change will be saved in the display machine data that is not visible to the user.
Remedy:
--
100351
Display MD cannot be accepted
Definitions:
Saving the display machine data was rejected by the NCK.
Remedy:
--
100360
Logic drive data saved
Definitions:
--
Remedy:
--