List of Action Numbers
No. 69
Explanation
Activate program test (VDI signal: Program test).
Cause
1. Tool management is active.
2. The NCK channel is in a state other than "ready".
− Backing up tool data
Remedy
− Abort the program or process with the Reset key or
− wait for end of program
No. 70
Explanation
Deactivate program test (VDI signal: Program test).
Cause
The NCK channel is in a state other than "ready".
− Abort the program or process with the Reset key or
Remedy
− wait for end of program
No. 71
Explanation
Stop at the end of block preparation (alarm)
Cause
-
Remedy
-
No. 72
Explanation
Stop at the end of block preparation with subsequent reorganization of block processing
(alarm)
Cause
Nesting depth too great
− Wait until the preceding ASUB is complete or
Remedy
− Abort program
No. 73
Explanation
Conditional stop at block end. If, after continuation by means of an NC Start, there is still
a reason to stop "Stop at block end", the program stops again.
Cause
-
Remedy
-
3-844