Terminal Module; Terminal Module Tm15 - Siemens SINAMICS S120 Commissioning Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Diagnostics
3.1 Diagnostics via LEDs
LED
Color
Green/
orange
or
Red/
orange
3.1.4

Terminal Module

3.1.4.1

Terminal Module TM15

Table 3- 43
Meanings of the LEDs on the Terminal Module TM15
LED
Color
READY
-
Green
Orange
Red
Green/red
Green/
orange
or
Red/
orange
268
State
Description, cause
Flashing light
Component recognition via LED is activated (p0154).
Note:
Both options depend on the LED status when module
recognition is activated via p0154 = 1.
Status
Off
Electronics power supply is missing or outside permissible
tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
light
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
At least one fault is present in this component.
light
Note:
The LED is activated regardless of whether the
corresponding messages have been reconfigured.
Flashing light
Firmware is being downloaded.
0.5 Hz
Flashing light
Firmware download is complete. Wait for POWER ON
2 Hz
Flashing light
Component recognition via LED is activated (p0154).
Note:
Both options depend on the LED status when component
recognition is activated via p0154 = 1.
Description, cause
Commissioning Manual, (IH1), 01/2013, 6SL3097-4AF00-0BP3
Remedy
Remedy
Remedy and
acknowledge fault
Carry out a
POWER ON
Commissioning Manual

Advertisement

Table of Contents
loading