Sony IXS-6700-C Installation Manual page 60

Integrated routing system pack, integrated routing system
Table of Contents

Advertisement

Status indication item
Error code
Error code
Error symbol
E.27
SBUS
E.40
XPT
E.50
BT
E.70
FAN
E.72
TEMP
E.80
MEM
E.E1
SW
E.FF
PG
0000
Warning code
Error code
Error symbol
W.60
REF
W.61
W/S
(Nothing is displayed.)
2-8
Error description
S-BUS connection error
The S-BUS line is disconnected. (detected by using or not using the 75 Z
terminator.)
Cross point error
The presence or absence of the signal detected at the output terminal does
not match at the specified cross point.
Backup lithium battery (BT801) error
Displayed when the content of the setting data backed up by a battery can not
guaranteed immediately after the power is turned on or after the system is
reset.
Fan failure
The number of revolution of one or more fan installed in IXS-6700/IXS-6600 is
fewer than specified (including when the fan stops).
Temperature rise error
The temperature inside IXS-6700/IXS-6600 has increased exceeding the
specified.
ROM/RAM error
Write error of the checksum of ROM (IC902, IC903) or RAM (IC804 to IC807)
n
After the application software is upgraded and the system is restarted, this
error code is displayed only once. However, this is not an error.
Switch setting error
The switches S1201, S1202, S1203, and S1204 on the CA board have
different settings in the backup area and the main area.
Flash write error
The system does not start up because the program has not been downloaded
correctly.
CA board operation failure
Displayed temporarily after resetting in the normal state, and the display
changes to each status number. If "0000" remains displayed, the program is
not running.
Error description
Reference video signal error
Although the mode that switches the cross point by synchronizing it to the
reference signal is set, no reference signal is input.
Audio word sync signal error
Although the audio option is installed, no reference signal is input.
The backup CPU (CA-65) board is not installed or not operating correctly.
IXS-6600/6700