Sony IXS-6700-C Installation Manual page 41

Integrated routing system pack, integrated routing system
Table of Contents

Advertisement

6. 7 : Not used
8 :
Factory use only (valid only during startup)
Used for adjustment in the factory.
If this mode is executed, all of the setting data are
deleted. Before executing this mode, implement the
backup of the setup data using the attached BZR-20
software. After execution of the this mode, return
the setup data.
9 :
Factory use only
2
I
C EEPROM (serial ROM) data edit mode (valid
only during startup)
When this mode is executed, the critical informa-
tion on the service stored in the board may be
damaged. When the IXS-6700/IXS-6600 is acciden-
tally activated in this mode, immediately set this
switch to 0 and restart the IXS-6700/IXS-6600.
A, B : Not used
C :
Clears the system status log.
(Valid only during startup)
Clears the system status log.
D:
Initialization of setting (valid only during startup)
Returns all of the setup items to the default setup
when shipped from the factory. However, the IP
address is not initialized.
E :
Network setting mode (valid only during startup)
Used for the setting, such as the IP address setting
to connect the IXS-6700/IXS-6600 to the network.
For details, refer to Section 1-11.
F :
Forced program download mode (valid during
startup)
Used for service maintenance.
S2401
BIT1: AUTO/MANUAL (Fixed to ON)
For adjusting boards at production. Set this to ON for
normal operation.
BIT2: SWAP/NORMAL
ON: NORMAL
The system starts up from the normal flash ROM .
OFF: SWAP
The system starts up from the backup flash ROM.
IXS-6600/6700
IF-844 Board
<LED>
D1 (B-1): SRX
Lights in green about 0.015 second when it receives the
data from the S-BUS data link.
<Switch>
S1 (B-3) : RESET
Reset switch of MPU on the IF-844 board.
< LEDs on LE-264 Board >
D1: STATUS
Lights in green: When the system works normally.
Flashes in green: When warning is issued.
Flashes in red: When an error occurs.
D2: ACTIVE
Lights in green: When the CA-65 board is functioning as
the main machine.
Turns off: When the CA-65 board is functioning as the
backup machine.
D3: USR-DF
Lights in green: When the user's default value that has
been written in the flash memory is valid at the re-start of
the system. (S1202-8 is ON.)
Turns off: When the setup values that are used immediate-
ly before is valid at the re-start of the system.
ND1 :ERR CODE
The information to be displayed on ND1 can be selected
by the setting of the rotary switch S1204. (Refer to S1204.)
Brightness of the ND1 display becomes darker when it is
operating as a backup during the redundant operation than
when it is operating as the main machine. When no error is
issued, the character "6600" (when IXS-6600 is installed)
or "6700" (when IXS-6700 is installed) is displayed. (For
details of the error codes, refer to section "2-1-3. CA
Board Error Display".)
1-33