D1100 (A-4) : FPGA2
Operation status indication of FPGA2 (IC1100).
Lights : Operation in progress.
Turns off : Operation not in progress.
D1300 (A-9) : EPR2 MAIN
Status indication of rotary switch S1300 or CN1302.
Lights : MAIN is selected with S1300 or CN1302.
Turns off : MAIN is not selected with S1300 or CN1302.
D1301 (A-10) : EPR2 CNO1
Status indication of rotary switch S1300 or CN1302.
Lights : CNO1 is selected with S1300 or CN1302.
Turns off : CNO1 is not selected with S1300 or CN1302.
D1302 (A-4) : EPR2 CNO2
Status indication of rotary switch S1300 or CN1302.
Lights : CNO2 is selected with S1300 or CN1302.
Turns off : CNO2 is not selected with S1300 or CN1302.
D1400 (A-3) : CONFIG0
Initial status indication of FPGA0 (IC800).
Lights : Finished.
Turns off : Not finished.
D1401 (A-4) : CONFIG1
Initial status indication of FPGA1 (IC850).
Lights : Finished.
Turns off : Not finished.
D1402 (A-4) : CONFIG2
Initial status indication of FPGA2 (IC1100).
Lights : Finished.
Turns off : Not finished.
D1600 (A-4) : DSP0
Operation status indication of DSP0 (IC1600).
Lights : Operation in progress.
Turns off : Operation not in progress.
D1800 (A-4) : DSP1
Operation status indication of DSP1 (IC1800).
Lights : Operation in progress.
Turns off : Operation not in progress.
D2000 (A-3) : + + + + + 12 V CTRL
+12 V CTRL power operation status indication.
Lights : Operation in progress.
Turns off : Operation not in progress.
D2002 (A-3) : RESET
Status indication of board reset operation
Lights : Reset operation in progress.
Turns off : Reset operation not in progress.
IXS-6600/6700
D2003 (A-3) : + + + + + 12
+12 V power operation status indication.
Lights : Operation in progress.
Turns off : Operation not in progress.
D2011 (A-4) : + + + + + 1.2 V
+1.2 V power operation status indication.
Lights : Operation in progress.
Turns off : Operation not in progress.
D2012 (A-4) : + + + + + 1.5 V
+1.5 V power operation status indication.
Lights : Operation in progress.
Turns off : Operation not in progress.
D2013 (A-4) : + + + + + 2.5 V
+2.5 V power operation status indication.
Lights : Operation in progress.
Turns off : Operation not in progress.
<Switch>
S100 (A-9) : MON
For setting the resistor of CPU-DK3 on the DAP-39 board.
S500 (A-7) : TEST
Rotary switch for the status setting of CPU-DK3 on the
DAP-39 board.
S501 (A-8) : ID
For production service.
Default setting when shipped from the factory is all OFF.
S800 (A-8) : MAIN/BACKUP area switch
Selects the area of flash when starting up the CPU.
MAIN : MAIN area
BACKUP : BACKUP area
S1100 (B-8) : SETUP0-7
For production service.
Default setting when shipped from the factory is all OFF.
S1300 (A-10) : EPR2 SEL
Select the FPGA in which to write a program with the
rotary switch.
Default setting when shipped from the factory is all 0.
0 : Writes in the FPGA of the DAP-39 board.
1 : Writes in the FPGA of the CNO1 board.
2 : Writes in the FPGA of the CNO2 board.
3-15 : Not used.
S2000 (A-8) : RESET
Pressing this switch resets the DAP-39 board.