Sony IXS-6700-C Installation Manual page 40

Integrated routing system pack, integrated routing system
Table of Contents

Advertisement

BIT2, BIT3: S/P selector switch
. . . . . BIT2 : REMOTE1 A connector
. . . . . BIT3 : REMOTE1 B, C (B1, B2, C) connectors
Used to assign the IXS-6700/IXS-6600 either to the
primary station or to the secondary station when the IXS-
6700/IXS-6600 is connected to the S-BUS data link with
the above connector. Set BIT2 and BIT3 in accordance
with the connector used.
OPEN: PRIMARY (operates as primary station)
CLOSE: SECONDARY (operates as secondary station)
Even if the setting is changed while the power is on, the
operation mode is not updated.
In order to change the operation mode, change the setting.
Then either turn off the main power and back on, or press
the reset switch (S1) on the CA-65 board.
Set the two selector switches in accordance with the
desired operations as shown below.
Operation
IXS-6700/IXS-6600 operates P
as primary station.
REMOTE1 A is connected
to higher-level controller
(4093 x 4093 area control)
IXS-6700/IXS-6600 operates –
as secondary station
P:
PRIMARY
S:
SECONDARY
*1: When S1203-3 is "SECONDARY", S-BUS A become "SECONDARY"
automatically.
BIT4: Table data size selector switch
Used to select the S-BUS table data size that is output
when the unit operates as the primary station in the S-BUS
data link of REMOTE1.
Even when a setting is changed while the power is on, the
setting is reflected on the operation of the IXS-6700/IXS-
6600.
OPEN: 32 bytes
CLOSE: 128 bytes
BIT5, BIT6, BIT7 : Baud rate selector switch
. . . . . BIT5 : REMOTE1 A connector
. . . . . BIT6 : REMOTE1 B connector
. . . . . BIT7 : REMOTE1 C connector
Sets the baud rate when the IXS-6700/IXS-6600 is con-
nected to the S-BUS data link using the above connectors.
All of the equipment that are connected to the same S-BUS
data link must have the same setting for the baud rate
speed. Set BIT5 and BIT6 in accordance with the connec-
tors used. Even when a setting is changed while the power
is on, the setting is reflected on the operation of the IXS-
6700/IXS-6600.
If there is any possibility to disconnect the cables between
the equipment while they are operating, set the switch to
the OFF position.
OPEN: 1250 kbps
CLOSE: 312 kbps
BIT8: Not used
1-32
S1203-2
S1203-3
(S-BUS A P/S)
(S-BUS B P/S)
P
S
P
*1
S
S1204 (A-4) : Test rotary switch
Run the system with 0 (default) position of this switch.
n
Be aware that if S1204 is set to 8 or 9, the information
stored in the board may be damaged. In case of setting
S1204 to 8, all the information set in the IXS-6700/IXS-
6600 may be erased affecting the operation of the IXS-
6700/IXS-6600. In case of setting S1204 to 9, the informa-
2
tion in the I
C EEPROM will be possibly lost.
Factory setting
m
. When this switch is set to any position of 1 to 5 while
the power is on, the setting is reflected on the operation
of the IXS-6700/IXS-6600. Set this switch to 0 to return
to the normal operation.
. Even the setting is changed to A to F while the power is on,
the operation mode is not updated. In order to change the
operation mode to A to F, change the setting. Then re-start the
CA-65 board (either turn off the power and back on, or press
the reset switch (S1) on the CA-65 board). Set this switch to 0
and re-start the CA-65 board to return to the normal operation.
0 : Normal operation
The error that is detected first by self-diagnosis is indicat-
ed on the status indicator as an error code. The error code
that is displayed first, is kept stored until the CA-65 board
is re-started or until this switch is set to the position 5.
1 : Displays the station ID (valid during operation).
The station ID of the IXS-6700/IXS-6600 is displayed
on the status indicator.
2 : Display the total count of the errors (valid during
operation).
The total count of the errors that are detected by self-
diagnosis (decimal number) is displayed on the status
indicator.
When the reset switch (S1) on the CA-65 board is
pressed or this switch is set to "5", the total count is
reset to "0000".
3 : Displays the IP address (valid during operation).
The IP address set to the IXS-6700/IXS-6600 is
displayed on the status indicator.
4 : Displays the setting state of the switch (valid during
operation).
The contents of the switches S1202 and S1203 on the
CA-65 board are displayed on the status indicator in
hexadecimal.
5 : Resets the error indication of status indicator (valid
during operation).
When returning the rotary switch from 5 to 0, the error
code displayed on the status indicator is reset, and
either "6600" (when IXS-6600 is installed) or "6700"
(when IXS-6700 is installed) is displayed. The total
count of error detected by self-diagnosis is also reset.
IXS-6600/6700