S1201 (B-3): Station ID/ Unit ID setting switch
8-pin DIP switch
Factory setting (\ indicates the switch lever position.)
Sets the station ID of the IXS-6700/IXS-6600 when the
IXS-6700/IXS-6600 is connected to the S-BUS data link as
follows.
When the IXS-6700/IXS-6600 is used as the primary
station, the station ID is set to "1" regardless of setting of
this switch.
When the IXS-6700/IXS-6600 is used as the secondary
station, set the station ID to any number other than "0", "1"
and "255". Be careful not to duplicate the same number of
the other equipment in the secondary station when setting
the station ID.
Sets the unit ID that is the 4th byte of the IP address using
the DIP switch (S1202-4 is set to OFF) when the IXS-
6700/IXS-6600 is connected to DATA LAN (Ethernet).
For details, refer to Section 1-11.
Even if the setting is changed while the power is on, the
station/unit ID is not updated.
In order to change the station/unit ID, change the setting.
Then either turn off the main power and back on, or press
the reset switch (S1) on the CA-65 board.
Setup example
1
0
[1]
[16] [32] [64] [128]
[2]
[4]
[8]
<Setting value>
8 :
0 0 0 1 0 0 0 0
30 :
0 1 1 1 1 0 0 0
(16 + 8 + 4 + 2)
254 :
0 1 1 1 1 1 1 1
(128 + 64 + 32 + 16 + 8 + 4 + 2)
1-30
When the setting value is 8
1 ; ON
0 ; OFF
S1202 (B-4)
8-pin DIP switch
Factory setting (\ indicates the switch lever position.)
BIT1 : Virtual matrix function valid/invalid
selector switch
Set this switch when you want to use the virtual matrix
function. Even if the setting is changed while the power is
on, the operation mode is not updated.
In order to change the operation mode, change the setting.
Then either turn off the power and back on, or press the
reset switch (S1) on the CA-65 board.
ON :
Virtual matrix functions.
OFF : Virtual matrix does not function.
BIT2 : Cross-level function valid/invalid selector
switch
Set this switch when you want to enable the cross-level
function. Even if the setting is changed while the power is
on, the operation mode is not updated.
In order to change the operation mode, change the setting.
Then either turn off the power and back on, or press the
reset switch (S1) on the CA-65 board.
ON :
Cross-level function is made valid.
OFF : Cross-level function is made invalid.
BIT3 : Tie Line full display function valid/invalid
selector switch
Set this switch when you want to enable the cross-level tie line
full display function when the tie line system is constructed
using the IXS-6700/IXS-6600. Even if the setting is
changed while the power is on, the operation mode is not
updated.
In order to change the operation mode, change the setting.
Then either turn off the power and back on, or press the
reset switch (S1) on the CA-65 board.
ON :
Tie line full display function is made valid.
OFF : Tie line full display function is made invalid.
n
For detailed description of the tie line full display function,
refer to Appendix B of the System Setup Manual: Glossary
"Tie line display function."