Table 9-2 Event Log Entries Unique To The Equipment - Hitachi HF-W100E Instruction Manual

Table of Contents

Advertisement

9. TROUBLESHOOTING
Table 9-2 lists event log entries unique to the equipment. No.1 through 6 are collected in the
system log, and Nos.7 and 8 are collected in the application log.

Table 9-2 Event Log Entries Unique to the Equipment (1/1)

Event
No.
Source
ID
1
259 HFWRAS_S
YS
2
263 HFWRAS_S
YS
3
265 HFWRAS_S
YS
4
268 HFWRAS_S
YS
5
525 HFWRAS_S
YS
6
539 HFWRAS_S
YS
7
769 HFWRAS_A
PP
8
771 HFWRAS_A
PP
No.3
: %1 denotes the drive bay number. %2 denotes the manufacturer and the model name of
the drive.
No.5
: %1 denotes the slot number of the DIMM.
No.6
: %1 records one of the following :
TEMP, MEM, CPU, TEMPLOG, WDT, SMART, RASLOG, INTERNAL – LOGD
No.7
: %1 denotes the function terminated with an error. %2 denotes the error code.
No.8
: %1 denotes the registry key that has an illegal value. %2 denotes the default value of the
registry key.
Type
Description
Warning
The temperature
exceeded prescribed
value.
Information Temperature returned to
prescribed value.
Warning
A failure may be
imminent on the drive
of the mSATA SSD%1
(%2).
Error
The computer was shut
down because
temperature became
dangerous.
Information In the DIMM %1, error
correcting have
occurred with high
frequency.
Error
The "%1" was finished. Hardware monitoring of the RAS
Error
An error occurred
in %1. errorcode = %2.
Error
Because a wrong value
is set up in registry
value "%1", default
value %2 is set up.
9-16
Action
Read the description of abnormal
temperature in "9.2.2 Problems that
occur after the OS startup (1) The
alarm lamp is lit" and take action
accordingly.
No handling
We recommend you back up the data
and replace the drive.
Read the description of abnormal
temperature in "9.2.2 Problems that
occur after the OS startup (1) The
alarm lamp is lit" and take action
accordingly.
The DIMM may be out of order.
Contact your system administrator or
maintenance personnel.
software has been terminated. If
restarting the equipment does not
resolve the error, contact the system
administrator or maintenance
personnel.
An error was generated by the RAS
software while the software was
running. If restarting the equipment
does not resolve the error, contact the
system administrator or maintenance
personnel.
If restarting the equipment does not
resolve the error, contact the system
administrator or maintenance
personnel.

Advertisement

Table of Contents
loading