7. Thread the right hand lock nut and turnbuckle onto the right hand rod end approximately
two turns. Turnbuckle length is a function of actuator size. (Refer to Table 7 on page 57.).
8. Secure the magnet housing assembly, including the lever and right hand rod end, to the
bracket using four M5 X 10 mm flat head screws.
9. Attach the left hand threaded rod end to the take-off rod with 1⁄4 - 20 UNC nut and thread
the left hand lock nut onto the rod end.
10. Thread the turnbuckle onto the left hand threaded rod end. Refer to Figure 25 on page 56.
11. Adjust the turnbuckle until the hole in the SVI FF lever is aligned with the indicating hole in
the bracket. Tighten both turnbuckle lock nuts. See Figure 23 on page 55.
12. Mount the SVI FF to the bracket and secure with four M6 socket head cap screws.
Table 7 Reciprocating Valve Mounting Hole and Turnbuckle Length
Actuator Size
Masoneilan
6 and 10
10
10
16
© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
Magnets
Ring
Figure 26 Magnet Holder for Reciprocating Valves
Stroke
0.5 - 0.8"
A
(12.7 - 20.32 mm)
0.5 - 0.8"
A
(12.7 - 20.32 mm)
>0.8 – 1.5"
B
(20.32 - 38.1 mm)
0.5 - 0.8"
B
(12.7 - 20.32 mm)
Housing
Lever
Magnet holder assembly
Mounting Hole
Lever Hole
A
A
B
A
Turnbuckle Length
1.25"
(31.75 mm)
1.25"
(31.75 mm)
1.25"
(31.75 mm)
2.90"
(73.66 mm)
Masoneilan SVI FF Instruction Manual