3.1.6
Current controller
Properties
S PI controller for current control
S Four identical current setpoint filters
S Current and torque limitation
S Current controller adaptation
S Flux control
Current control
No settings are required for operating the current controller. The controller can be
optimized for special applications (see Subsection 3.1.8).
Current and torque limitation
The current and torque limitations are initialized when the system is commissioned
for the first time and should be adjusted according to the application.
© Siemens AG, 2005. All rights reserved
SINAMICS S120 Function Manual, 06/05 Edition
Lower torque limit all torque limits without offset
CI: Torque limit, upper/motoring, scaling
CI: Torque limit, lower/regenerating scaling
Motor mode power limit
Power limit, regenerative mode
Torque offset torque limit
Maximum torque-generating current of all current limits
CO: Torque limit, upper total
CO: Torque limit, lower total
Maximum motor-mode torque-generating current limit
Minimum regenerative-mode torque-generating current
CO: Upper effective torque limit
CO: Lower effective torque limit
Operating Modes
Servo control
3-77