Current Setpoint Filter - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

3.2.10

Current setpoint filter

Description
The two current setpoint filters connected in series can be parameterized as fol-
lows:
S Low-pass 2nd order (PT2): --40dB/decade)
S General filter 2nd order
Band-stop and low-pass with reduction are converted to the parameters of the
general filter 2nd order via STARTER.
-- Band-stop
-- Low-pass with reduction by a constant value
The phase frequency curve is shown alongside the amplitude log frequency curve.
A phase shift results in a control system delay and should be kept to a minimum.
Overview of key parameters (see List Manual)
S p1655
S p1666
Function diagram overview (see List Manual)
S 6710
© Siemens AG, 2005. All rights reserved
SINAMICS S120 Function Manual, 06/05 Edition
CI: Current setpoint filter natural frequency tuning
Current setpoint filter 2 numerator damping
Current setpoint filter
Operating Modes
Vector control
3-133

Advertisement

Table of Contents
loading

Table of Contents