Table 3-16
Parameters
p0640
p1080
p1082
p1120
p1121
p1135
The optional motor data can be entered (if known). Otherwise, it can be estimated
on the basis of the type plate data, or by means of motor identification or speed
controller optimization.
© Siemens AG, 2005. All rights reserved
SINAMICS S120 Function Manual, 06/05 Edition
Optional data, continued
Description
Current limit
Minimum speed
Maximum rotational speed
Ramp-function generator
ramp-up time
Ramp-function generator
ramp-down time
OFF3 ramp-down time
Notes on commissioning vector motor types
This value is limited to maximum
4 * p0305.
This value is defaulted to 1.5 *
p0305 during commissioning.
--
This value can be less than or
equal to p0322.
--
--
--