Operating Modes
Notes on commissioning vector motor types
The following parameters can be entered when the commissioning Wizard is run in
STARTER:
Table 3-15
Parameters
p0304
p0305
p0311
p0314
p0316
If the torque constant k
can be calculated as follows using the rated motor data or the standstill current I
and standstill torque M
M
N
k
=
=
T
I
N
M
o
k
=
T
I
o
Table 3-16
Parameters
p0320
p0322
p0323
p0328
p0341
p0342
p0344
p0350
p0356
p0357
3-158
Motor data
Description
Rated motor voltage
Rated motor current
Rated motor speed
Motor pole pair number
Motor torque constant
is not specified on the type plate or on the data sheet, it
T
):
o
60
s
* P
N
min
or
2π * n
* I
N
N
Optional data
Description
Motor rated magnetization
current/short-circuit current
Maximum motor speed
Maximum motor current
PE spindle, reluctance torque
constant
Motor moment of inertia
Ratio between the total and
motor moment of inertia
Motor weight
Motor stator resistance, cold
Motor stator leakage inductance
Lq
Motor stator leakage inductance
Ld
Note
If this value is not known, "0" can
also be entered. This value
enables the stator leakage
inductance (p0356, p0357) to be
calculated more accurately.
--
--
--
--
Note
This is used for the field
weakening characteristic
Maximum mechanical speed
De-magnetization protection
--
For speed controller pre-control
--
For thermal motor model, not
relevant for synchronous motors
--
--
--
© Siemens AG, 2005. All rights reserved
SINAMICS S120 Function Manual, 06/05 Edition