Hardware Preparation and Installation

MVME162LX Installation

2
!
Caution
!
Warning
2-16
With EPROMs and IPs installed and headers properly configured,
proceed as follows to install the MVME162LX in the VME chassis:
1. Turn all equipment power OFF and disconnect the power
cable from the AC power source.
Inserting or removing modules while power is applied
could result in damage to module components.
Dangerous voltages, capable of causing death, are
present in this equipment. Use extreme caution when
handling, testing, and adjusting.
2. Remove the chassis cover as instructed in the user's manual
for the equipment.
3. Remove the filler panel from the card slot where you are
going to install the MVME162LX.
– If you intend to use the MVME162LX as system controller,
it must occupy the leftmost card slot (slot 1). The system
controller must be in slot 1 to correctly initiate the bus-
grant daisy-chain and to ensure proper operation of the
IACK daisy-chain driver.
– If you do not intend to use the MVME162LX as system
controller, it can occupy any unused double-height card
slot.
4. Slide the MVME162LX into the selected card slot. Be sure the
module is seated properly in the P1 and P2 connectors on the
backplane. Do not damage or bend connector pins.
5. Secure the MVME162LX in the chassis with the screws
provided, making good contact with the transverse mounting
rails to minimize RF emissions.