Network Setting for Each PLC Type
When PLC Type is Panasonic: FP
1.
After selecting the PLC type, press "Set"
button of "PLC Communication Setting".
The setting window for Panasonic FP series is
displayed.
2.
Assign the IP address to the PLC.
3.
Specify the port number of the PLC.
Input the same number as the port number set on
the PLC to communicate.
Available port No. on PV500: 1 to 32767 (except
8600 to 8699 and 9090)
4.
Select whether to limit the PLC to communicate by setting "Specify Station No." or not.
Station Home (Default):
A command which specifies no station number is issued.
Example) %EE#WDD0001 × × × × ×
Specify Station No. (Station No. 1 - 99)
A command for a PLC with the specified station number is issued. Specify the same number of the station
number that is set for the PLC to communicate in "Station No.".
Example) When Station No. is 50
When PLC Type is Panasonic: FP (ET-LAN unit)
1.
After selecting the PLC type, specify the PV
station No. in "PV Station No.".
Selectable station No.: 1 – 64
2.
Press "Set" button of "PLC Communication
Setting".
The setting window for Panasonic FP series
(ET-LAN unit) is displayed.
3.
Assign the IP address to the PLC.
4.
Specify the port number of the PLC.
Input the same number as the port number set on the PLC to communicate.
Available port No. on PV500: 1 to 32767 (except 8600 to 8699 and 9090)
5.
Specify the station number of the PLC.
Settable Range: 1 – 64
Specify the station number of the PLC to communicate. The number specified in the step 1 "PV Station
No." cannot be used.
%50#WDD0001 × × × × ×