ASSIGN 0 - 5 (ASN0-5): Function Assignment (* partly)
Use this signal to perform the function shown in the table below by a signal from the external device.
To assign a function to Assign signal, select "ENVIRONMENT" > "Input/Output" > "Parallel I/O" in SETUP
menu.
Template Setting (*):
Switch Run/Stop:
Save Data in PV (*):
Save Data in SD (*):
Read Data from PV (*):
Read Data from SD (*):
Reinspect:
Reset Statistics (*):
Reset Error (*):
Save Image Memory in SD (*):
Output Latest Image(*):
Clear Image Memory (*):
Print Screen (*):
Abort Inspection/Process
Abort Save/read Setting Data
IN0 - 15: Input data
These are signals to input the values for switching type, reading/saving setting data when you execute the
functions. Specify values in binary data as follows.
Example 1) Specifying No.6
Example 2) Specifying No.237
The same as REENTRY
The same as RUN/STOP
All product type data currently registered in "execution memory" will be
saved in "memory for store" of PV. Specify a storing area number (0 - 99)
with "IN0 - IN6".
All product type data currently registered in "execution memory" will be
saved in a SD memory card. Specify a storing area number (0 - 99) with
"IN0 - IN6".
The setting data registered in the storage space in PV500 will be called
up to "execution memory". Specify a reading area number (0 - 99) with
"IN0 - IN6".
The product type data registered in a SD memory card will be called up to
"execution memory" of PV.
Input this to reinspect without capturing an image. Enter a block number
(0 - 9) to execute with "IN0 - IN3".
Input this to clear the statistics data and scan count.
ERROR 0 and ERROR 1 will be turned off.
Backs up all images saved in the image memory to a SD memory card.
Creates a folder named one of "00" to "99" which does not exist in
"Panasonic MEW VIsion¥PV500¥Image¥Backup" in a SD memory card
and saves images in the folder.
Outputs the latest inspection image.
The destination (SD memory card or PC connected with Ethernet cable)
and the file name can be set from "ENVIRONMENT" > "Input/Output" >
"Image Output" menu.
In "ENVIRONMENT" > "Input/Output" > "Image Output", set
"Output Conditions" to "Command Reception".
Image Receiver needs to be activated on the destination PC when
"Destination" is set to "Ethernet".
All image data registered in the Storage Space in PV500 will be cleared.
The currently displayed screen (entire contents the monitor displaying)
will be captured and saved in a SD memory card or a PC through
Ethernet.
You can specify destination from "ENVIRONMENT" > "Input/Output" >
"Print Screen".
Cancels the following active operations, and restores into the previous
status before the operation.
Cancellation of the operation of a serial command which has been
received
Abort of the status waiting for Individual trigger input
Abort of output in the status waiting for result output after an
inspection is complete
Abort of image saving from Image Memory to a SD memory card
Cancellation of template re-registration
Cancels saving or reading the setting data.
IN7
IN6
IN5
IN4
0
0
0
0
IN7
IN6
IN5
IN4
1
1
1
0
IN3
IN2
IN1
IN0
0
1
1
0
IN3
IN2
IN1
IN0
1
1
0
1
369