Deleting a Base Checker
With Position Adjustment - Binary Edge/ Gray Edge/ Smart Edge (Line), adjusting only either of horizontally or
vertically can be performed. To delete (restore to be unset) the horizontal base checker or vertical base
checker that has been "Set", operate from the pop-up menu.
1.
Move the cursor onto the set base checker to
delete.
2.
Press the FUNC key.
The pop-up menu appears.
3.
Select "Delete".
When the dialog message appears, select "YES".
The selected base checker is deleted and "Status" field
changes to "Unset".
Registering Base Position
Register the current object position as a base position.
·
When the displayed image is a live image, Position Adjustment scans a newly captured image and the
detected position and angle are registered as a base. When displaying a memory image, it scans the
currently displayed image and the detected position and angle are registered as a base.
·
Displaying a message other than "Register a Base Position," in the message display area indicates that
the checker could not detect an object in a base checker test. Change the setting of a base checker
with NG display in the judgement field.
Position Adjustment - Binary Edge, Gray Edge, Smart Edge
(Circle), Smart Edge (Line), Position Rotation Adjustment -
Smart Edge (Line) and Rotation Adjustment
1.
Select "Base Position".
2.
Select "Register".
3.
When the dialog message appears,
select "YES".
Correctly registering a base position
displays values in the list of Adjustment
Amount, Current Position, Base Position,
and Base Checker.
If a base position cannot be registered,
return to the Condition setting window and
reconsider the settings of the base checker
judged as NG.
205