Specifying Checker No.
1.
Select "Connector (Gra. Edg.)" in "Checker Type".
2.
Select the checker No. list and specify a checker
number to set.
3.
Press the ENTER key to determine the checker No.
"Connector (Gra. Edg.)" setting window is displayed. The
gray image is displayed on the screen window.
Selecting a Camera
Select a camera image to set Connector (Gray Edge) checker.
1.
Select "Area Setting" in "Connector (Gra. Edg.)" setting window.
2.
Select a camera No. in "Camera".
The selected camera image is displayed.
Select a displayed image type (Live/Memory or Gray/Binary) or magnification in "Image Menu" opened by
pressing the F1 key.
Selecting Preprocess / Slice Level / Position
Adjustment
page 95
Selecting an Execution Mode and Checker Direction
Connector (Gray Edge) checker has four execution modes. Select one of them according to your inspection
purpose.
Checker Direction is to set a start point and an end point of an area horizontally or vertically. Changing either of
Execution Mode or Checker Direction clears an inspection area. Set them before drawing an area.
1.
Select "Inspection Condition" in "Connector (Gra. Edg.)" setting window.
2.
Select one of four modes for
"Execution Mode".
When the dialog message appears,
select "YES".
3.
Select "Horizontal" or "Vertical" in
"Checker Direction".
When the dialog message appears,
select "YES".
Now, selecting Execution Mode and
Checker Direction is complete.
152
Execution Mode = Pitch
Execution Mode
= Width Measurement