4.18.2 Data R/W in RUN Menu

Data R/W 0 -3 are displayed in the designated window, Data R/W 0 window - Data R/W 3 window. In RUN
menu, the following operations can be done; selecting a window to display, changing the position and size, and
displaying frame (rule lines).
Refer to Chapter 5.3.2 Arranging Layout (page 320).
Displaying Data R/W
1.
Select "VIEW" from the menu bar in RUN menu.
The menu appears.
2.
Select "Data R/W".
Marked off Data R/W window is displayed and others are not displayed.
3.
Select a window number of Data R/W to display.
The selected number of Data R/W window is marked off and displayed.
Asterisk symbol (*) shown in a cell indicates that not all digits of the value can be displayed within the width
of the current cell. Adjust the cell width to display the all digits.
In RUN menu, you can change the outlook of Data R/W including the window size and cell width. Refer to
page 322 for details.
To hide the displayed Data R/W window
Select "Data R/W" from "VIEW" menu and select the number of Data R/W window to hide.
Changing Values Using Data R/W
While displaying Data R/W window, you can change the data registered in Data R/W. (Some data cannot be
changed such as results.)
It is helpful to execute inspections changing values frequently (when introducing PV500), or to permit changing
some limited values (when using password for limitation of switch to the SETUP menu to prevent to change the
setting data by mistake).
If any parameter other than values is registered in Data R/W, it will be replaced with a value to display. The item
name will not be displayed. When changing the setting, the item name is displayed in the subwindow.
Example) When the preprocess group selected in a checker has been registered in Data R/W
Preprocess
Display in Data R/W
No
A
B
C
D
E
0
1
2
3
4
5