Issue 01/06
P0304[3]
Rated motor voltage
CStat:
C
P-Group: MOTOR
Nominal motor voltage [V] from rating plate. Following diagram shows a typical rating plate with the
locations of the relevant motor data.
Line supply voltage
MICROMASTER 410
MICROMASTER 411
MICROMASTER 420
MICROMASTER 430
MICROMASTER 440
*) Line supply voltage 1-ph. 110 V AC is stepped-up --> frequency inverter output voltage 3-ph. 230 V AC
Index:
P0304[0] : 1st. Drive data set (DDS)
P0304[1] : 2nd. Drive data set (DDS)
P0304[2] : 3rd. Drive data set (DDS)
Dependency:
-
Changeable only when P0010 = 1 (quick commissioning).
-
Default value is depending on inverter type and its rating data.
Caution:
The input of rating plate data must correspond with the wiring of the motor (star / delta). This means, if delta
wiring is used for the motor, delta rating plate data has to be entered.
IEC Motor
W2
U2
U1
V1
U1
V1
W1
Delta connection
e.g.: Volts 230 V (Delta connection) / 400 V (Star connection)
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Datatype: U16
Active: first confirm
1 AC 110 V *)
1 AC 230 V
X
X
-
-
-
X
-
-
-
X
W2
U2
V2
V2
U1
V1
W1
W1
U1
V1
W1
Star connection
Parameter Description
Min:
10
Unit: V
Def:
230
QuickComm.: Yes
Max:
2000
3 AC 230 V
3 AC 400 V
-
-
-
X
X
X
-
X
X
X
Level
1
3 AC 500 V
-
-
-
-
X
51