Co: Current Setpoint Isd; Co: Act. Current Isd; Co: Current Setpoint Isq; Co: Act. Current Isq - Siemens MICROMASTER 440 Parameter Manual

0.12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Parameter Description
r0075

CO: Current setpoint Isd

P-Group: CONTROL
Displays setpoint of flux generating current component.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
r0076

CO: Act. current Isd

P-Group: CONTROL
Displays flux generating current component.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
r0077

CO: Current setpoint Isq

P-Group: CONTROL
Displays setpoint for component of torque generating current.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
r0078

CO: Act. current Isq

P-Group: CONTROL
Displays component of torque generating current.
r0079
CO: Torque setpoint (total)
P-Group: CONTROL
Displays total torque setpoint.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
r0080
CO: Act. torque
P-Group: CONTROL
Displays actual torque. Output value will be zero at low frequencies when current injection is active (r1751.5
= 1).
r0084
CO: Act. air gap flux
P-Group: CONTROL
Displays air gap flux in [%] relative to the rated motor flux.
r0086
CO: Act. active current
P-Group: CONTROL
Displays active (real part) of motor current.
Dependency:
Applies when V/f control is selected in P1300 (control mode); otherwise, the display shows the value zero.
r0090
CO: Act. rotor angle
P-Group: CONTROL
Indicates the current angle of the rotor. This function is not available on single input channel encoders.
40
Datatype: Float
Unit: A
Datatype: Float
Unit: A
Datatype: Float
Unit: A
Datatype: Float
Unit: A
Datatype: Float
Unit: Nm
Datatype: Float
Unit: Nm
Datatype: Float
Unit: %
Datatype: Float
Unit: A
Datatype: Float
Unit: °
Issue 01/06
Min:
-
Def:
-
Max:
-
Min:
-
Def:
-
Max:
-
Min:
-
Def:
-
Max:
-
Min:
-
Def:
-
Max:
-
Min:
-
Def:
-
Max:
-
Min:
-
Def:
-
Max:
-
Min:
-
Def:
-
Max:
-
Min:
-
Def:
-
Max:
-
Min:
-
Def:
-
Max:
-
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Level
3
Level
3
Level
3
Level
3
Level
3
Level
4
Level
4
Level
3
Level
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents