Issue 01/06
2.2

Quick commissioning (P0010 = 1)

The following parameters are necessary for quick commissioning (P0010 = 1).
Quick commissioning (P0010 = 1)
Par.-No.
P0100
P0205
P0300
P0304
P0305
P0307
P0308
P0309
P0310
P0311
P0320
P0335
P0640
P0700
P1000
P1080
P1082
P1120
P1121
P1135
P1300
P1500
P1910
P1960
P3900
When P0010 = 1 is chosen, P0003 (user access level) can be used to select the
parameters to be accessed. This parameter also allows selection of a user-defined
parameter list for quick commissioning.
At the end of the quick commissioning sequence, set P3900 = 1 to carry out the
necessary motor calculations and clear all other parameters (not included in P0010
= 1) to their default settings.
Note
This applies only in Quick Commissioning mode.

Reset to Factory default

To reset all parameters to the factory default settings; the following parameters should
be set as follows:
Set P0010 = 30
Set P0970 = 1
Note
The reset process takes approximately 10 seconds to complete. Reset to Factory
default
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Name
Europe / North America
Inverter application
Select motor type
Motor voltage rating
Motor current rating
Motor power rating
Motor cosPhi rating
Motor efficiency rating
Motor frequency rating
Motor speed rating
Motor magnetizing current
Motor cooling
Motor overload factor [%]
Selection of command source
Selection of frequency setpoint
Min. speed
Max. speed
Ramp-up time
Ramp-down time
OFF3 ramp-down time
Control mode
Selection of torque setpoint
Select motor data identification
Speed control optimisation
End of quick commissioning
Parameters
Access level
Cstat
1
C
3
C
2
C
1
C
1
C
1
C
1
C
1
C
1
C
1
C
3
CT
2
CT
2
CUT
1
CT
1
CT
1
CUT
1
CT
1
CUT
1
CUT
2
CUT
2
CT
2
CT
2
CT
3
CT
1
C
15