Toshiba GRL100-701B Instruction Manual page 203

Grl100-7**b series. line differential relay
Table of Contents

Advertisement

AB
BC
UV2
UVS1
A
B
UV3
UVG1
A
B
CTF
CTFID
AB
BC
VTF
UVFS
Autoreclose
OVB UVB SYN1 OVL1 UVL1 SYN2 OVL2 UVL2 OVL1
Line 1 shows the operation status of current differential elements for phase faults and earth
faults, respectively.
Line 2 shows the status of the out-of-step protection. α and β is "1" when the remote terminal
voltage is at α -zone and β -zone respectively. OST shows the operation status of out-of-step
element. OST1 and OST2 correspond to the out-of-step detection with remote terminal 1 and 2
respectively.
Line 3 shows the status of the overcurrent element for breaker failure protection.
Line 4 shows the status of the overcurrent elements and fail-safe elements.
Line 5 shows the status of the thermal overload element.
Line 6 shows the status of the broken conductor detection element.
Lines 7 and 8 show the status of the distance measuring element for phase and earth faults.
Lines 9 and 10 show the status of the blinder element and power swing blocking element.
Line 11 shows the status of the overcurrent element and directional earth fault element.
Lines 12 to 16 show the status of the overvoltage elements and undervoltage elements.
Lines 17 and 18 show the status of elements used for CTF and VTF detection.
Line 19 shows the status of elements used for autoreclose.
The status of each element is expressed with logical level "1" or "0". Status "1" means the
element is in operation.
To display all the lines on the LCD, press the
4.2.4.4
Displaying the Status of the Time Synchronization Source
The internal clock of the GRL100 can be synchronized with external clocks such as the IRIG-B
time standard signal clock or RSM (relay setting and monitoring system) clock or by an
IEC60870-5-103 control system or GPS. To display on the LCD whether these clocks are active
or inactive and which clock the relay is synchronized with, do the following:
• Select 2 (=Status) on the top "MENU" screen to display the "Status" screen.
• Select 4 (=Time sync source) to display the status of time synchronization sources.
/ 2
* I R I G :
R S M :
I E C :
G P S :
CA
AB
BC
CA
UVS2
C
A
B
C
UVG2
C
A
B
C
CTFUV
CA
A
B
C
UVFG
T i m e s y n c
h r o n i z a t o n
A c t i v
e
I n
a c t i v e
I n
a c t i v e
I n
a c t i v e
 202 
AB
BC
CA
UVSBLK
A
B
C
UVGBLK
CTF
OVG
OVG
(3PH)
and
keys.
i
s o u r c e
6 F 2 S 0 8 5 0
3 /
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grl100-702bGrl100-711bGrl100-712b

Table of Contents