CAUTION!
You will be handling the IVP8 when it is most fragile — unpacked and exposed. The IVP8, if
handled properly, will give long, reliable service. To ensure that the unit is not damaged
during installation or maintenance, follow these precautions.
Damage may not always be immediately evident (e.g., no physical damage on the outside of
the unit) and system failure may result weeks or months later.
Handle the IVP8 with care. Mechanical shock from dropping, shaking, excessive force
when seating the board into the slot, rocking a connector on or other activities can
severely damage the disk assembly or the disk's printed circuit board.
Wear the anti-static wrist strap included in the package. It can also be re-used and left
with the Strata CTX or Strata DK cabinet. An electrostatic charge from your body can
damage the drive or circuitry permanently.
Hold the IVP8 by the edges or the strap and never touch the board's surface. Pressure on
the printed circuit board or contaminants from your hands (e.g., skin oil, food particles,
hand lotion) can cause component failure.

Step 2: Program Strata

Strata CTX Systems

DTMF Signaling
Stratagy is compatible with all Strata CTXs. Strata CTX needs to recognize Stratagy's DTMF
signaling. An ARCS card must be installed in the Strata CTX100 for this DTMF signaling. Strata
CTX670 allows four DTMF circuits in its default configuration.
Install and program an ARCS card in the Strata CTX100. When installed, the ARCS card by
default allows four circuits. Additional licenses may be required, depending upon the
Strata CTX configuration and applications.
SMDI
Are you going to have SMDI? SMDI is required for the Call Record feature with
Stratagy Release 3.3. A BSIS card must be located close to the Stratagy.
1. Install and program serial card BSIS in the Strata CTX. Refer to the Strata CTX Programming
Manual.
2. A serial cable must be installed between the BSIS card and the Stratagy. Toshiba's PPTC-9
(with six-conductor line-cord) is recommended.
3. Stratagy's serial Port 1 is reserved for SMDI communication.
IVP8
To the Strata CTX processor, the IVP8 functions as an analog card (RSTU). Although there are
some special program settings required for the IVP8 (e.g., DSS/BLF feature), the Strata CTX
should be programmed just as it would for any external voice mail system that is to be connected
to it.
Stratagy I&M
06/02
Installation
Step 2: Program Strata