IM 308-C master interface and memory card
Code for operat-
ing-system version
3-12
Before the IM 308-C operating system is loaded from the memory card, the
four LEDs on the IM 308-C output a flashing BCD code which indicates the
current statuses of the operating system on the IM 308-C and on the memory
card.
You can call up the code indicating which version of the operating system is
currently available on the IM 308-C (see steps 1 through 6, Table 3-9), when
the mode selector switch of the IM 308-C is in the "OFF" position and you
switch on the power supply.
Table 3-9 Flashing code output by LEDs on IM 308-C when the operating system is

loaded from memory card

3
RN
2
2
2
OF
1
2
BF
0
2
IF
Step
1
3
in sequence from bottom to top
2
all LEDs are off
3
BCD code indicating the current operating-system
version of the IM 308-C
4
all LEDs are off
5
BCD code indicating the current operating system
release of the IM 308-C
6
all LEDs are off
7
3
from top to bottom in sequence
8
all LEDs are off
9
BCD code indicating the operating-system version on
the memory card
10
all LEDs are off
11
BCD code indicating the operating-system release on
the memory card
12
all LEDs are off
V x.y
Version
Release
LED sequence
ET 200 Distributed I/O System
EWA 4NEB 780 6000-02a
Duration
3 s
1 s
4 s
1 s
4 s
1 s
3 s
1 s
4 s
1 s
4 s
1 s

Hide quick links: