Siemens SIMATIC S5 Manual page 271

Ip 266 positioning module
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

IP 266
8.1.5
Programmer
The module is equipped with two 15-pin D subminiature interfaces. The pro-
grammer must be connected to the one at the right.
FAULT
ANALOG
OUT
E
N
C
P
O
G
D
E
R
6
POSITIONING
MODULE IP 266
6ES5 266-8MA11
1 2 3 4 5 6
Figure 8-1. Location of the Programmer Interface and
C A U T I O N :
The programmer interface and the encoder interface both have 15 pins, and it is
possible to confuse the two. Remember that the programmer interface is the
one on the right.
If you confuse the two, the module executes a Reset.
EWA 4NEB 812 6057-02
1
2
9
3
10
4
11
5
12
6
13
7
14
8
15
Connector Pin Assignments
Start-Up
Pin
Description
1
Shield
2
RxD
N
_
3
-
4
-
P
5
-
G
6
TxD
P
_
7
TxD
N
_
8
Shield
9
RxD
P
_
10 to 15
-
8-5