IP 266
Data area:
Field name
Type
Module:
O
These fields are the same as those in the data area on page 1.
Meas.System:
Axis type:
Reference
I
The drive begins a reference point approach at this speed. Reference
speed 1:
speed 1 is the higher of the two speeds for the initial approach to
reference point, and must be less than or equal to the maximum speed.
Reference
I
The IP 266 requires this speed for an exact approach to the reference
speed 2:
point. Reference speed 2 must be less than or equal to the maximum
speed and less than or equal to reference speed 1.
Reference
I
Defines the direction for the reference point approach. Use <F7> to
direction:
choose between 'forward' and 'reverse'.
Pulses/
I
Specifies the number of pulses per encoder revolution (this information
revolution:
can be obtained from the encoder's rating plate).
Travel/
I
The distance traversed per encoder revolution must be entered in this
revolution:
field. The value must take into account all ratios between encoder and
axis.
PLC BCD coded:
I
When you select "yes" with <F7>, all coordinates transferred from the
PLC are interpreted in BCD code. The value range in BCD format is
restricted to +/-9999999 µm.
Polarity HW limit
I
This field is used to indicate which edge of the limit switch or "External
switch:
Stop" signal is to be evaluated.
"Type" column: I = input field, O = output field
The "travel/pulses" resolution is computed from the values for "travel/revo-
lution" and "pulses/revolution"
EWA 4NEB 812 6057-02