Status

Device related Status Messages appear at the top of the
Projectionist Terminal Screen in the area normally
occupied by the Current User information and the Date &
Time. This Status Message area is common to all screens
and the messages appear when the Status Indicator Lamp
is flashing red or yellow. Tap the Close button to remove
the Status Message from the Projectionist Terminal.
Status Messages
Status Message
SMS Computer is Off-line
Encl Temp exceeded Err Level
PDU is Off-line
Media Block Error
RAID is not ready
UPS: Abnormal Condition
UPS: Replace Battery
System Status Warning indicators/buttons appear along
the bottom of the Projectionist Terminal basic screen.
Tap for Menu
Status
Lamps &
Selector
Buttons
Tap for

Power Status

Tap for

Lamp Status

The Status indicators are common to all screens and when
tapped directly access the various system status panes.
Under normal conditions their appearance is as sown in the
illustration.
When you tap an indicator to access the
associated Status pane its appearance
changes as shown to the right.
When the associated sub-system is in alarm
the appearance of the indicator changes as
shown to the right.
18
Status
Status Lamp
Red/Flash
Red/Flash
Red/Flash
Red/Flash
Red/Flash
Yellow/Flash
Yellow/Flash
Close
Status Messages
Tap for
Tap for
Fan Status
Message
Tap for
Temperature Status
The monitored sub-systems are grouped as follows:
• Power Status
• Lamp Status
• Fan Status
• Temperature Status
An additional indicator on the far right is provided to
notify the operator when a system Message is present.
Each individual Status pane presents views of the status of
the subsystems of the Digital Cinema auditorium unit.
Indicators on the system status panes have three possible
states. They are
(GREEN) - Operation Normal
(RED) - Error/Warning
(GRAY) - State Unknown
Power Status
To view the Power Status pane, from any
Projectionist Terminal display, tap the
Power Status icon. The POWER
STATUS pane appears (illustrated below)
and displays status indicators for each of the following
PROJECTOR sub-systems.
• The projector signal processor sub-systems
(PR-01 - PR-04).
• The signal input sub-systems (IF A through IF D).
• The 16V and 24V supplies
Lamp Status
The LAMP STATUS pane provides information about the
two Xenon Arc lamps, the percentage of usable life used,
when they were last replaced, and status of monitored
states in the Lamp sub-system.
To view the Lamp Status pane, from any
Projectionist Terminal display, tap the
Lamp Status icon. The LAMP STATUS
pane appears (illustrated below) and
displays an information area and status/alarm indicators