(19) RS485 connection diagram 19)
* 4
GOT side
SDA1
1
SDB1
2
RDA1
3
RDB1
4
SDA2
5
SDB2
6
RDA2
7
RDB2
8
SG
9
FG
10
*1
Pin No. of control equipment differs depending on the model. Refer to the following table
*2
Terminating resistor should be provided for an Interface converter and a control equipment which will be terminals.
*3
Connect FG grounding to the single-sided end of a cable shield line.
*4
Set the terminating resistor of GOT as follows.
Set the terminating resistor setting switch of the GOT main unit to "Disable".
➠ ■3.
Terminating resistor(150Ω 1/2W)
Control equipment side
* 1
DA
DB
SG
* 3
Signal name
SDC45/46
Pin No.
DA
C10
DB
C11
SG
C12
Connecting terminating resistors
* 2
* 3
Model of control equipment
CMS
MQV
CMF015
MPC
Pin No.
Pin No.
5
7
6
8
10
9
3.3 Connection Diagram
Control
equipment
side
* 1
DA
DB
SG
MVF
RX
Pin No.
Pin No.
1
1
2
2
7
3
3 - 51
3

Advertisement