Mitsubishi Electric Q26UD(E)HCPU User Manual page 503

Melsecq series
Hide thumbs Also See for Q26UD(E)HCPU:
Table of Contents

Advertisement

Number
Name
CH1 pulse
Starts pulse
SM1898
measurement
measurement.
start command
CH1 error reset
SM1899
Resets the CH1 error.
command
OFF: Coincidence point
CH2 counter
SM1900
value greater
ON: Greater than
(No.1)
CH2 counter
value
OFF: Not detected
SM1901
coincidence
ON: Detected
(No.1)
OFF: Coincidence point
CH2 counter
SM1902
value smaller
ON: Smaller than
(No.1)
OFF: Coincidence point
CH2 counter
SM1903
value greater
ON: Greater than
(No.2)
CH2 counter
value
OFF: Not detected
SM1904
coincidence
ON: Detected
(No.2)
OFF: Coincidence point
CH2 counter
SM1905
value smaller
ON: Smaller than
(No.2)
CH2 external
preset (phase Z)
OFF: Not detected
SM1906
request
ON: Detected
detection
OFF: No error
SM1907
CH2 Error
ON: Error
OFF: No warning
SM1908
CH2 warning
ON: Warning
Meaning
• This relay is turned on to measure pulses.
• The command is valid while this relay is
on.
• This relay is turned on to reset the CH1
error.
• The command is valid at the rise of this
relay (off  on).
• The on and off time must be held for at
least 2ms.
• This relay turns on when "current value of
CH2 > coincidence output No.1 point
(No.1) or smaller
setting value" is met.
• This relay turns off when "current value of
coincidence point
CH2  coincidence output No.1 point
(No.1)
setting value" is met.
• This relay turns on when "current value of
CH2 = coincidence output No.1 point
setting value" is met.
• This relay is turned off by turning on CH2
coincidence signal No.1 reset command.
• This relay turns on when "current value of
CH2 < coincidence output No.1 point
(No.1) or greater
setting value" is met.
• This relay turns off when "current value of
coincidence point
CH2  coincidence output No.1 point
(No.1)
setting value" is met.
• This relay turns on when "current value of
CH2 > coincidence output No.2 point
(No.2) or smaller
setting value" is met.
• This relay turns off when "current value of
coincidence point
CH2  coincidence output No.2 point
(No.2)
setting value" is met.
• This relay turns on when "current value of
CH2 = coincidence output No.2 point
setting value" is met.
• This relay is turned off by turning on CH2
coincidence signal No.2 reset command.
• This relay turns on when "current value of
CH2 < coincidence output No.2 point
(No.2) or greater
setting value" is met.
• This relay turns off when "current value of
coincidence point
CH2  coincidence output No.2 point
(No.2)
setting value" is met.
• This relay turns on when a preset request
by phase Z (preset) terminal of CH2 is
detected.
• This relay is turned off by turning on CH2
external preset (phase Z) request
detection clear command.
• This relay turns on if the CH2 error
occurs.
• This relay turns off when an error cause is
removed and CH2 error reset command is
turned on.
• This relay turns on if a warning occurs in
CH2.
• This relay turns off when a warning cause
is removed and CH2 error reset command
is turned on.
Set by
Explanation
(When Set)
S (Every
END
processing)
S (Status
change/
Every END
processing)
S (Every
END
processing)
S (Every
END
processing)
S (Status
change/
Every END
processing)
S (Every
END
processing)
S (Every
END
processing)
S (Every
END
processing)
S (Every
END
processing)
APPENDICES
Corresponding
Corresponding
ACPU
CPU
M9
U
New
LCPU
U
New
LCPU
New
LCPU
New
LCPU
New
LCPU
New
LCPU
New
LCPU
New
LCPU
New
LCPU
New
LCPU
New
LCPU
A
501