Note:
•
When updating LPAR manager firmware version to 01-4X or later, check if
the following mezzanine cards are used or not. If one of cards is used in
the server blade, you may need to update the card firmware.
- Emulex 10 Gb CNA/LAN mezzanine card
- Onboard CNA
•
For about combination of LPAR manager firmware version and firmware
version for mezzanine cards, see the Hitachi Compute Blade 500 Series
Logical partitioning manager User's Guide.
•
In the non-redundant management module configuration, when replacing
the management module because of a failure, the LPAR manager
firmware is lost and re-installation is required. We recommend deploy the
redundant management module configuration.
•
The LPAR manager cannot be operable even when an LPAR manager
firmware version is installed in a bank. Select the LPAR manager firmware
bank for the server blade. Selecting the LPAR manager firmware bank is
available from the management module console.
•
If a management module is switched when you execute update on the
management module console, the update fails. Remove the error factor
and then execute update again.
•
When LPAR manager firmware is being installed on a bank assigned to a
server blade, powering on the server blade is prevented.
•
When LPAR manager firmware is being installed, the target bank for
installation cannot be assigned to a server blade.
Obtaining LPAR manager firmware
For obtaining LPAR manager firmware, contact <contact information>.
Note:
Hitachi Compute Blade 500 Series Management Module Setup Guide
Functional detail
2-197