Commissioning The Camera With Heater Option Fitted - Bosch MIC612 Operation Manual

Hide thumbs Also See for MIC612:
Table of Contents

Advertisement

MIC612 Thermal Camera
27. If connecting to additional add-on cards (for example, a card for 8-input alarms (MIC-
ALM), and/or a Biphase card (MIC-BP4)), remove the second blanking plug that covers one of
the holes for an M12 cable gland (item 3 in the figure "MIC PSU Enclosure, with cable glands
identified"). Attach the supplied M12 gland. Make the appropriate connections to plug-in
terminal CN2.
Notice!
For installation of the MIC 8-input Alarm Card (MIC-ALM) or Biphase converter (MIC-BP4),
please refer to their respective manuals.
28. After wiring is complete, connect the power supply to the power source.
29. Verify that the following LEDs are lit:
LED
LED 2
LED 4
LED 3
LED 5
30. Re-attach the enclosure lid and tighten the four (4) captive screws on the cover to ensure
that the enclosure is watertight.
5.9

Commissioning the Camera with Heater Option Fitted

To enable the heaters, you must change two links on the printed circuit board (PCB) of the
power supply. Follow these steps:
1.
2.
Bosch Security Systems
Description
18 VAC power on to camera
Power on for optional heater
18 VAC power on camera
Power on for optional heater
Disconnect the power supply from the power source.
Locate Link 1 and Link 2 on the PCB, next to terminal block HD6. The default setting is
0V.
Operation Manual
Install the MIC (standard) PSU | en
2016.03 | 2.1 | F.01U.249.416
25