Operation of the Thermal Camera

10.1

Switching Video

To switch Video Channel 2 between the optical (visible) camera and the thermal camera, enter
the Thermal Camera Setup menu of the OSD, select the option Second Channel Video, and
then toggle to the appropriate choice.
10.2

Flat-Field Correction (FFC)

The thermal camera uses an internal process called flat-field correction (FFC) to improve the
quality of the thermal video image displayed on the monitor. During this process, a shutter
rotates in front of the Focal Plane Array (FPA) to give a uniform temperature (a flat field) to
every detector element. During the process (which takes less than a second), the live thermal
video image is frozen, and persists, while the camera updates correction coefficients. After the
process completes, live video returns automatically. With a more uniform array output, the
quality of the image should improve.
About 2 seconds before an automatic FFC operation, the thermal camera displays a small
green square in the upper right of the video output. This square symbol is called the Flat Field
Imminent Symbol; it warns that FFC is about to begin.
Figure 10.1: Thermal image with Flat Field Imminent Symbol (green square)
Performing FFC often should prevent the thermal video image from appearing "grainy". This is
especially important when the temperature of the camera is fluctuating, such as immediately
after the camera is powered on, or when ambient temperature is changing.
10.3

Displaying Thermal Camera Temperature

The thermal camera can display its internal temperature on the video output with a SPOT
meter (320 TVL models only).
1.
2.
Notice!
The selected settings should remain in internal memory; if you must turn off power to the
camera, the camera should retain the last meter display and the temperature scale (°F/°C);
those should appear after power on.
Bosch Security Systems
In Bosch protocol, in the OSD, enter "Aux ON + 463 + ENTER." The message, "SPOT meter
Display: ON" should appear on-screen, and the SPOT meter should appear.
Note: entering "Aux OFF + 463 +ENTER" deactivates the SPOT meter.
Select the appropriate temperature scale. Enter "Aux ON + 463 + ENTER" again to toggle
the temperature scale as necessary. (The default scale is in Degrees F.)
Operation Manual
Operation of the Thermal Camera | en
2016.03 | 2.1 | F.01U.249.416
71