Utility; Utility-Diagnosis - Panasonic KX-TDA100 Programming Manual

Hybrid ip-pbx, pc programming manual
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

2.6 Utility

2.6.1 Utility—Diagnosis
Performs diagnostic tests on cards installed in the PBX, to identify the source of problems.
If any of the tests listed here returns the result "NG" ("No Good"), contact your dealer. Test results can be
saved as a TXT-format (text) file.
When testing is complete, any cards that were set to OUS status must be returned to INS status if they are to
be used again.
Card Test
Tests the relevant functions of a card to ensure that it is operating correctly. The tests carried out vary according
to the type of card being tested.
The tests that are performed on each card are as follows:
KX-TDA30
Test Type
Local loop back diagnosis
Card CT Bus diagnosis
DTMF Receive test port
MSG/SVM Card DTMF receive test
EXT-CID path test
DSP DTMF generator/receiver
diagnosis
DSP DTMF receiver diagnosis
Framer IC alarm signal detection
diagnosis
Framer IC error detection diagnosis
KX-TDA100/KX-TDA200/KX-TDA600
Test Type
Local loop back diagnosis
Card CT Bus diagnosis (KX-TDA100/
KX-TDA200 only)
DTMF Receive test port
PT loop back diagnosis
DHLC4, DLC8, SLC4, SLC8, IP-EXT4, LCOT, DID3, BRI, IP-GW4,
SIP-GW4, E1
DLC8, SLC8, IP-EXT4, IP-GW4, SIP-GW4, E1
DHLC4, SLC4, SLC8
MSG2, SVM2, ESVM2
EXT-CID
E1
E1
E1
E1
DHLC, DLC, SLC8, SLC16, MSLC16, ESLC16, EMSLC16, CSLC16,
ECSLC24, CSIF, LCOT, ELCOT, T1, E1, BRI, PRI, OPB, E&M, DID,
IP-EXT16
DHLC, DLC, SLC8, SLC16, MSLC16, ESLC16, EMSLC16, CSLC16,
CSIF, LCOT, ELCOT, T1, E1, BRI, PRI, OPB, E&M, DID, IP-EXT16
DHLC, SLC8, SLC16, MSLC16, ESLC16, EMSLC16, CSLC16,
ECSLC24, E&M, DID
DHLC, DLC
2.6.1 Utility—Diagnosis
Available Cards
Available Cards