EAS28040
CHECKING THE RELAYS
Check each switch for continuity with the pocket
tester. If the continuity reading is incorrect, re-
place the relay.
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
1. Disconnect the relay from the wire harness.
2. Connect the pocket tester (Ω × 1) and battery
(12 V) to the relay terminals as shown.
Check the relay operation.
Out of specification → Replace.
Starter relay
3
R
B
4
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Result
Continuity
(between "3" and "4")
Relay unit (starting circuit cut-off relay)
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
R/L
L/W R/W
1
2
ELECTRICAL COMPONENTS
Result
Continuity
(between "3" and "4")
Relay unit (fuel pump relay)
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Result
Continuity
Headlight (on/off)/grip warmer relay
3
4
2
Y/W
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Result
Continuity
(between "3" and "4")
– 130 –
+
1
R/Y
G/L
R/Y