GE MDS 4790M Installation And Operation Manual page 54

400 mhz master station radio for mpt 1411 applications
Hide thumbs Also See for MDS 4790M:
Table of Contents

Advertisement

RADIO START-UP
MDS 4790 MAS Radio
ENTER
OWNERS NAME
OWNERS MESSAGE
ESCAPE
MDS 4790 MAS Radio
≥Configuration
Diagnostics
Event Log
ENTER
ESCAPE
Set Access Level
Set Access Level
User
Transmit Frequency
457.99375
Receive Frequency
463.49375
Output Power Setting
37 dBm
Modem
9600
Baudrate/Format
9600 8N1
Emphasis
disabled
Clear to Send Delay
25 milliseconds
Push to Talk Delay
0 milliseconds
Soft Carrier De-key
0 milliseconds
Transmit Timeout
enabled
Transmit Timeout
55 Seconds
Rx Timeout
none
Repeater Mode
disabled
RX Mute Mode
disabled
Continuous Keying
disabled
Manual Key
disabled
Unit Address
6682
Key On Data
disabled
46
MDS 4790 MAS Radio
≥Configuration
Diagnostics
Event Log
ESCAPE
TO CHANGE
SETTING:
ENTER
ENTER
CONFIGURATION
SCREENS (CONTINUED)
Data Buffering
enabled
Diagnostic Link
enabled
DLINK Baudrate
4800
Diagnostic Type
Root
TX Audio Level
-20 dBm
RX Audio Level
-20 dBm
Transmit Gain
disabled
Receive Pad
disabled
Alarm Masks
Major None
Minor None
Alarm Sense is HI
Display Contrast
0
50
100
Backlight Intensity
0
50
100
Set Owner Name
OWNERS NAME
Set Owner Message
OWNERS MESSAGE
Set Time
Set Time
11:34:57 AM
12:03:51 AM
Sep 14 2000
Oct 01 1999
Set Date
11:34:57 PM
Sep 14 2000
ESCAPE
Figure 22. Front Panel Screen Flowchart
MDS 4790M (MPT 1411) I/O Guide
Invisible place holder
MDS 4790 MAS Radio
Configuration
≥Diagnostics
Event Log
ENTER
Operating Status
TX: dekeyed
RSSI:: -60 dBm
S/N: 10 dB
Active Radio Status
no alarms present
Rx Signal Strength
-60 dBm
S/N Ratio
10 dB
Radio Selection
AUTO
Radio A is Active
Transmitter Status
dekeyed
Show Temp/Voltage
30° Celcius
14.7 Volts Input
10.1 Volts Output
Serial Number
A: 12345678
B: NOT EQUIPPED
Software Revision
06-3321A01
1.5.1 1FEB2000
ESCAPE
MDS 4790 MAS Radio
Configuration
Diagnostics
≥Event Log
TO CHANGE
ENTER
SETTING:
ENTER
ENTER
LOG 1 OF 1
4/29/00 12:00:00
System Boot
Clear Logs
ESCAPE
TO CHANGE
SETTING:
ENTER
ENTER
MDS 05-3628A01, Rev. B

Advertisement

Table of Contents
loading

Table of Contents