MDS 05-3628A01, Rev. B
Table 2. Feedline Loss Chart (450 MHz)
3.05 Meters
Cable Type
(10 Feet)
RG-8A/U
0.51 dB
1/2 in. HELIAX
0.15 dB
7/8 in. HELIAX
0.08 dB
1-1/4 in. HELIAX
0.06 dB
1-5/8 in. HELIAX
0.05 dB

4.0 INSTALLATION PROCEDURES

This section presents the steps necessary for installing the radio and connecting
it to associated equipment. After completing these steps, the radio will be ready
for in-service operation.

4.1 Unpacking and Inspection

Figure 6 shows a typical radio shipment. Check the contents against the
packing list secured to the outside of the shipping box. Accessories and spare
parts kits, if any, are wrapped separately. Inspect all items for signs of damage.
Save all packing materials in case you need to ship the radio in the future.
ADHESIVE FEET (4)*
(For tabletop mounting)
PC DIAGNOSTICS & CONTROL
DISK (OPTIONAL)
Figure 6. Typical Shipment Contents
MDS 4790M (MPT 1411) I/O Guide
15.24 Meters
30.48 Meters
(50 Feet)
(100 Feet)
2.53 dB
5.07 dB
0.76 dB
1.51 dB
0.42 dB
0.83 dB
0.31 dB
0.62 dB
0.26 dB
0.52 dB
Invisible place holder
POWER CORD
(AC cord shown)
INSTALLATION
& OPERATION GUIDE
* These items may already be installed
on the radio chassis.
152.4 Meters
(500 Feet)
25.35 dB
7.55 dB
4.15 dB
3.10 dB
2.60 dB
RACK-MOUNT BRACKETS (2)*