SAFETY INFORMATION CAUTION CAUTION VARING - INVISIBLE LASER RADIATION WHEN OPEN AND - OSYNLING LASERSTRÅLNING NÄR DENNADEL ÄR INTERLOCKS DEFEATED. AVOID EXPOSURE TO BEAM. ÖPPNAD OCH SPÄRRAR ÄR URKOPPLADE. STRÅLEN ÄR FARLIG. CLASS 1 VARO! - AVATTAESSAJASUOJALUKITUS OHITETTAESSAOLET ADVARSEL - USYNLIG LASERSTRÅLING NÅR DEKSEL ÅPNES OG ALTTIINANÄKTMÄTÖNTÄ...
SERVICE SAFETY PRECAUTIONS Replacing the fuses CAUTION: FOR CONTINUED PROTECTION AGAINST THE RISK OF FIRE REPLACE ONLY WITH SAME TYPE OF FUSE. Reference No Part Number Description M507 *AH 5120-0052-0 FUSE T1.6A 250V 5X20MM M512, M513 *AH 5120-0020-0 FU T1A 250V UL/CSA 5X20 M514 5120-0026-0 FU T315MA L 250V UL/CSA...
REAR PANEL / FRONT PANEL REAR PANEL 1. LINE OUT 3. NAD LINK 2. DIGITAL OUT 4. AC LINE CORD FRONT PANEL 1. POWER ON / OFF 7. STOP 2. DISC DRAWER 8. REPEAT 3. DISPLAY 9. RANDOM 4. OPEN 10.
DISASSEMBLY INSTRUCTIONS 1. Remove machine screws M 4.0 x 6.0 ( 1 to 4 ) from the side panels. Remove tapping screw 3.0 x 8.5 5 from the back panel. Refer to Figure No.1. Figure No.1 2. Pull both sides of the TOP COVER slightly outwards 6 and tilt approx. 35˚ and then remove in the direction as indicated by the arrow 7 .
J334 Testing Point R132 NAD - C 541 PCB TESTING POINTS DIAGRAM TESTING PROCEDURE (1) Load the test disc (Sony Test CD YEDS-7) and set the unit into PLAY mode. (2) Connect the scope to R132 (Pin 41 of U101) and DGND (J334).
IMPORTANT NOTES INSTRUCTION FOR HANDLING OPTICAL SYSTEM BLOCK PICK-UP Electrostatic breakdown of the laser diode in the optical system block may occur due to a poten- tial difference caused by electrostatic charge accumulated on clothing, human body, etc. A ground must be provided as follows to prevent any electrostatic charge during unpacking or repair work.
Page 11
PRECAUTIONS WHEN CHANGING LASER PICK-UP When removing the pick-up assembly, short circuit the PCB tracks on the optical block as show in the drawing in order to protect the pick-up before removal. NOTE: Replacement pick-up assemblies are supplied with the PCB pattern already protected. DO NOT REMOVE THE SHORT CIRCUITS UNTIL YOU HAVE FINISHED FITTING THE PICK- Protective soldering place for laser diode...
TROUBLESHOOTING GUIDE SET POWER SWITCH TO ON. CHECK FUSES CHECK POWER SUPPLY POWER SUPPLY PATTERNS OPEN IS POWER TURNED ON ? M507, M512-M514 OPEN ? CIRCUIT NORMAL ? OR U501-U507 DEFECTIVE. IS OSCILLATOR CIRCUIT M507,M512-M514 DEFECTIVE CRYSTAL M401 DEFECTIVE. OSCILLATING ? IS THERE OPEN/ CLOSE KEY SIGNAL M101 SWITCH, DEFECTIVE CAN TRAY BE OPENED ?
REMOTE CONTROL HANDSET 1497-1302-1 REMOTE CONTROL POLYBAG 4301-4105-0 INSTRUCTION MANUAL 1497-1062-0 MANUAL POLYBAG 1435-4200-1-2 CARTON BOX Proprietary information for servicing purposes only. The information herein may not be used com- mercially without the prior written agreement of NAD Electronics International, Toronto, Canada.