MIC Power Supply Units (PSUs) for Non-IR MIC Cameras

The figure below displays the layout of the PCB in the MIC PSUs for non-IR cameras, with call-
out numbers to the side of or below the connection/terminal ID or the terminal, and 'on' the
fuses. The table below the figure identifies the connections.
Figure 3.3 Layout of PCB in enclosure of PSU for non-IR MIC cameras
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
F.01U.265.804 | 1.6 | 2012.08
Connection /
Terminal ID on PCB
HD1
AC Power input
HD3
Shielded composite cable
(analog connections to camera)
HD5
RS-485 control
HD4
USB to RS-485 converter
HD8
**NOT USED**
HD6
[Optional] Auxiliary, heater
HD7
Video (composite cable)
HD2
Tamper switch
CN3 (Video Switched) Coax connection
CN1 (Video Out)
Coax connection
CN2
Auxiliary card header
Earth Link
Earth Link
FS2
Fuse 2 - Primary protection
FS1
Fuse 1 - MIC camera protection --
FS3
Fuse 3 - Heater protection 1
FS5
Fuse 5 - Heater protection 2
User Manual
Description/Function of
Connection / Terminal
MIC Series IP Power Supply
Type of Connection /
Terminal
Screw terminal
Screw terminal
Screw terminal
Molex connector
Molex connector
Screw terminal
Screw terminal
Screw terminal
BNC socket
BNC socket
Plug in
--
--
--
--
Bosch Security Systems, Inc.