Each MIC power supply unit (PSU) provides all of the connections needed for power, video,
and telemetry for a single MIC camera. Each MIC PSU has CE and FCC approval and has an
aluminum enclosure that is weather-resistant (rated IP67). Features include:
The table below summarizes the MIC power supplies and their specifications:
MIC PSU
MIC-IP-PS-115
MIC-IP-PS-230
MIC-IP-PS-24
Dimensions
(H x W x D)
Weight
MIC-IPIR-PS-115 115 VAC 50/60 Hz 60 VA 18 VAC
MIC-IPIR-PS-230 230 VAC 50/60 Hz 60 VA 18 VAC
MIC-IPIR-PS-24 24 VAC 50/60 Hz 60 VA 18 VAC
Dimensions
(H x W x D)
Weight
3.1

Parts List

Each MIC IP PSU ships with the following parts:
3.1.1

User-Supplied Parts

Installers must provide the following parts to complete installation of a MIC PSU:
3.1.2

User-Supplied Tools

F.01U.265.804 | 1.6 | 2012.08
A built-in encoder for video and data transmission over an IP (standard 10/100 Base-T)
network
A provision for driving various optional interface cards mounted internally to the MIC
power supply enclosure (for example, an 8-input alarm card (MIC-ALM))
A provision for a signal interface card (MIC-BP4) to connect telemetry to Bosch Biphase
equipment
Screw termination of all cables (composite, telemetry, and ancillary) into and out of the
enclosure
Earth isolation and termination within the unit to control video earthing correctly and
thus prevent earth loops
Voltage Hz
115 VAC 50/60 Hz 40 VA 18 VAC
230 VAC 50/60 Hz 40 VA 18 VAC
24 VAC 50/60 Hz 40 VA 18 VAC
330 x 250 x 90.75 mm
13 x 9.8 x 3.6 in.)
7.21 kg (15.9 lb)
330 x 250 x 90.75 mm
(13 x 9.8 x 3.6 in.)
7.3 kg (16.09 lb)
Two (2) M12 cable glands for telemetry and ancillary equipment
One (1) M16 gland for connection of RJ45 or Fiber cable
One (1) 1/2 in. NPT cable gland for connection of the shielded composite cable to the
MIC camera
One (1) 1/2 in. NPT cable gland for the power cable connection
One (1) 1/2 in. NPT and one (1) M12 blanking plug
Power cable in the appropriate length
Four (4) M6 stainless steel screws and washers
Metal conduit suitable for containing power cables external to the PSU enclosure
Ethernet cable (terminated as needed)
Ring crimp tool (Davico type DHCR15 or equivalent)
Phillips-head screwdriver
Power Output Applicable MIC Cameras
IP Power Supply Units (Non-IR)
MIC550, MIC612
IP IR Power Supply Units
MIC550IR
User Manual
MIC Series IP Power Supply
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents