4.13

Flowmeter - Operation

The incoming water turns an impeller that contains a magnet located in
the Flow Meter Axle. As the impeller turns, an external Reed Switch is
switched on / off by the effect of the magnet. The electronic monitors
the number of pulses to determine the volume of incoming water.
Approximately 200 pulses = 1 liter.
1 Reed Switch
2 Housing
3 Magnet (could also be mounted directly on an impeller blade)
4 Impeller
5 Housing cap
Figure 4-8: Flowmeter Assembly Components (External Flowmeter Shown)